UNIVERSAL AERIAL/DUCT CABLES#

OPTIX Cable STEEL Z-XOTKtc 1.2kN (up to 60m SPAN – NESC Heavy)

9/125 ITU-T G.652D

FEATURES
  • Universal cable for aerial/canalization installation
  • Span (NESC Heavy) up to 60 meters (1.2kN)
  • Better structural strength
  • Resistance to high and low temperatures
  • Water blocking construction
  • Solid HDPE jacket

CABLE CONSTRUCTION#

  1. Optical fibres in 0.25mm coloured coating
  2. Hydrophobic jelly
  3. Loose tube
  4. Water blocking yarns
  5. Steel rods
  6. Ripcords to tear the outer jacket
  7. HDPE outer jacket (black), UV stabilized


The OPTIX Z-XOTKtc cable: A light single-tube construction, great flexibility and durability against dragging. Water blocking gel and construction (WB), moisure absorbing threads (WSY), HDPE coating, UV radiation resistant, working temperature range: -40°C - 70°C, reinforced with 2 steel rods. Z-XOTKtc equivalent. Maximum installation tension: 1200N.


All cable fibres are colour coded according to the "EIA/TIA-598" standard. The tube has up to 24 fibreglass threads and is filled with a hydrophobic gel for protecting the threads against moisture and vibration. The core of the cable is protectedagainst moisture intrusion with the help of moisture absorbing yarns.


For additional construction durability steel ∅ 0.9mm rods have been molten into the outerPE layer. Two ripcords have also been molten into the coating that make the removal of the outer layer easier. The cables are meant for installation in primary and secondary tele-technical canalisation by pneumatic (cable blowing) and mechanical (cable jetting) means, as well as for aerial installation on a span of up to 60m.


OPTIX Cable STEEL Z-XOTKtc 1.2kN (up to 60m SPAN – NESC Heavy)

Product information
Cable
version
The total
amount of
fibres {pcs}
Weight
{kg/km}
(±10%)

Cable
{mm}
(±0.4)

Tube
{mm}
(±0.15)
Supporting
element/
Peripheral
reinforcement
Reinforcing
element
{mm (±0.1)
Coating
material
& thickness
(mm) (±0.2)
Temp.
range
instalation
Temp.
range
operating
transport
Minimum
bending
radius
temporary
permanent
1T4F 4 40 6.5 1.4/2.0) None Steel(2x0.9) HDPE(2.0) -10° to +50°C -40° to +70°C 20D/15D
1T8F 8 40 6.5 1.4/2.0) None Steel(2x0.9) HDPE(2.0) -10° to +50°C -40° to +70°C 20D/15D
1T12F 12 40 6.5 1.4/2.0) None Steel(2x0.9) HDPE(2.0) -10° to +50°C -40° to +70°C 20D/15D
1T24F 24 50 7.0 1.6/2.4) None Steel(2x0.9) HDPE(2.0) -10° to +50°C -40° to +70°C 20D/15D


Mechanical parameters EN standard IEC standard 1-8F 12F 24F
Tensile Strength Installation (NESC Heavy) EN 187000 IEC 60794-1-2-E1 1200N 1200N 1200N
Tensile Strength Operation (NESC Heavy) EN 187000 IEC 60794-1-2-E1 600N 600N 600N
Crushing resistance EN 187000, m.504 IEC 60794-1-2-E3 500N (100x100mm) for 60 sec.
Repeated bending EN 187000, m.507 IEC 60794-1-2-E6 30 cycles [(20xD), 1kg]